ELCBs
poles_number: 1
Specifications:
1) Applicable circuit: AC 50Hz (or 60Hz)
2) Rated insulation voltage: 690V
3) Rated operating voltage: up to 660V (690V)
4) Rated operating voltage: up to 250V (DC)
5) Rated operating current: 20 - 100A
6) For distributing energy of electricity and infrequent making and
breaking circuit, and infrequent starting of motor (rated operating
current up to 400A)
7) At normal condition they are provided with the function of protection
against overload and short-circuit and under-voltage
8) MCCB complies with standard of IEC947-2, GB14048.2 and GB14048.4
9) Number of poles: 3P
10) Leakage including high speed type and time delay type
11) High speed type
a) Rated current sensitivity (30-100-500mA)
b) Max. operating time (0.1S)
12) Time delay type
a) Rated current sensitivity (100.300.500)
b) Max. operating time under 21In (0.45.1.0.2.0S)
c) Inertial no operating time under 21In (0.1.0.5.1.0S)
13) Weight: 1.20kg
14) Automatic tripping device: thermal-magnetic type
Specifications:
1) Applicable circuit: AC 50Hz (or 60Hz)
2) Rated insulation voltage: 690V
3) Rated operating voltage: up to 660V (690V)
4) Rated operating voltage: up to 250V (DC)
5) Rated operating current: 20 - 100A
6) For distributing energy of electricity and infrequent making and
breaking circuit, and infrequent starting of motor (rated operating
current up to 400A)
7) At normal condition they are provided with the function of protection
against overload and short-circuit and under-voltage
8) MCCB complies with standard of IEC947-2, GB14048.2 and GB14048.4
9) Number of poles: 3P
10) Leakage including high speed type and time delay type
11) High speed type
a) Rated current sensitivity (30-100-500mA)
b) Max. operating time (0.1S)
12) Time delay type
a) Rated current sensitivity (100.300.500)
b) Max. operating time under 21In (0.45.1.0.2.0S)
c) Inertial no operating time under 21In (0.1.0.5.1.0S)
13) Weight: 1.20kg
14) Automatic tripping device: thermal-magnetic type
Sales Terms & Specifications:
| Model No. | ELCB series |
|---|---|
| Place Of Origin | China |
| Brand Name | powemake |
| Price Terms | FOB / CIF / EXW(Factory Price) |
| Terms Of Payment | T/T, L/C at sight |
| Supply Ability | 2,000pcs/day |
| Delivery Lead Time | Within 45 days after receipt of L/C or T/T |
Relative Products
RDX2-100 MINI CIRCUIT BREAKER type: MiniAPPLICATION : The product used to protect line-conductor and overload, and short-circuit of small sealedmot | Mini Circuit Breaker type: MiniIn=63A~125A
Icn=15kA
C, D type, 1P~4P
Double break points in series, arc extinction system
Indicated of switch on and | Leakage Breaker type: Minipoles_number: 3It is applicable to office buildings and dwelling houses. Its rated residual
non-action current is 15, |
Moulded case circuit breaker type: Moulded Caseit is suitable for ships and land, in the circuit with AC50/60HZ, rated insulationvoltage 660V or less,rate cu | Moulded Case Circuit Breaker poles_number: 1type: Moulded CaseIt is suitable for the distribution circuits of AC in 50/60Hz,working voltage upto 600V,used fo | circuit breaker type: Minipoles_number: 2Application The product carries out national standards GB14048,2-94 and accords with the internati |
Circuit Breaker We would like to help your company to produce components for Circuit breaker: ACB,VCB,MCCB,CB,MCBand its relative cover or compo | Electromagnetic Hydraumatic Circuit Breaker poles_number: 1type: MiniMode: EHB-30
Safety: GB17701-1999
Rated voltage: DC 65V, AC 250V
Rated current: 1 - 50A
Rated circuit c | Circuit Breaker poles_number: 1Application:
1) AC type
2) Operated by residual current
3) Adapted to domestic, public and industrial fields
4) |
Leakage Circuit Breaker poles_number: 1A type RCCB:
BF62/BF64 is an usually used AC and DC circuit. This item is in accordance with standards of IEC, ap | Surge Protective Device poles_number: 1Features:
1) Max. continuous operating voltage:150V AC
2) Voltage protection level up to:< 800V
3) Optic and ac | Sf6 Circuit Breaker type: AirLW36A-126 Outdoor AC SF6 circuit breaker is a control and protection device to the 50Hz AC and 110kV power system. It c |



view large photo of ELCBs
type: MiniAPPLICATION : The product used to protect line-conductor and overload, and short-circuit of small sealedmot
type: MiniIn=63A~125A
Icn=15kA
C, D type, 1P~4P
Double break points in series, arc extinction system
Indicated of switch on and
type: Minipoles_number: 3It is applicable to office buildings and dwelling houses. Its rated residual
non-action current is 15,
type: Moulded Caseit is suitable for ships and land, in the circuit with AC50/60HZ, rated insulationvoltage 660V or less,rate cu
poles_number: 1type: Moulded CaseIt is suitable for the distribution circuits of AC in 50/60Hz,working voltage upto 600V,used fo
type: Minipoles_number: 2Application The product carries out national standards GB14048,2-94 and accords with the internati
We would like to help your company to produce components for Circuit breaker: ACB,VCB,MCCB,CB,MCBand its relative cover or compo
poles_number: 1type: MiniMode: EHB-30
Safety: GB17701-1999
Rated voltage: DC 65V, AC 250V
Rated current: 1 - 50A
Rated circuit c
poles_number: 1Application:
1) AC type
2) Operated by residual current
3) Adapted to domestic, public and industrial fields
4)
poles_number: 1A type RCCB:
BF62/BF64 is an usually used AC and DC circuit. This item is in accordance with standards of IEC, ap
poles_number: 1Features:
1) Max. continuous operating voltage:150V AC
2) Voltage protection level up to:< 800V
3) Optic and ac
type: AirLW36A-126 Outdoor AC SF6 circuit breaker is a control and protection device to the 50Hz AC and 110kV power system. It c